Skip to main content
Rajesh_
Associate
July 25, 2019
Question

Configure PWM using eMIOS0 Channel 7

  • July 25, 2019
  • 1 reply
  • 647 views

When I look in the eMIOs Settings of the SPC560Bxx HAL Driver Component, I can only activate eMIOs group 0 (Channel 9..15) or Group1 (Channels 17..23) but as per my requirement i have to use Channel 7.

But channels 0 to 7 can only be activated by ICU drivers.

Is this right?

Is there an other way to activate PWM on these channels?

    This topic has been closed for replies.

    1 reply

    ppate.16
    Associate II
    September 12, 2019

    hi PWM driver ch u have to select according to the channel dedicated (9 to 15 or 17 to to 23) .