VL53L1X calibration process
Hi
Do we need to calibrate every sensor in the production line, or we just need to make the calibration once to the standard product?
Sensor: VL53L1X.
Thanks
Hi
Do we need to calibrate every sensor in the production line, or we just need to make the calibration once to the standard product?
Sensor: VL53L1X.
Thanks
Both of those are true.
The offset calibration must be done per device.
if you promise your glass quality is consistent and your production values are such that the air-gap between the glass and the sensor is consistent, then go ahead and crosstalk calibrate the first 100 of the line. Then use the worst of those calibration numbers in the rest of your production run, assuming they are all kind of close.
The reason for using the worst is the penalty for over calibrating is a slight under-range. The penalty for under calibrating is a false target. And you don't want that.