Question

Getting -3 inside the HCI_TL_SPI_Send always with Nucleo H7 and x cube Ble2.

  • August 18, 2022
  • 1 reply
  • 933 views

@@Hello, 

I am trying to run the sensor demo ble with Nucleo H7 and BRNG2A1 Nucleo board but I am getting error -3 always inside the HCI_TL_SPI_Send.

Attached is my ioc file. 

Can you please tell me what's wrong with this? I have followed the documentation inside the x-cube-ble2 for Nucleo 144 board. (STMicroelectronics.X-CUBE-BLE2_GettingStarted.pdf)

Best Regards,

P

    This topic has been closed for replies.

    1 reply

    PVaaz.1
    PVaaz.1Author
    Associate III
    August 19, 2022

    ok i fixed it. SPI settings were incorrect