ST7580 error code 0x08

  • November 14, 2023
  • 1 reply
  • 1247 views

I'm developing a power line communication with the ST7580. Sometimes I get an error code 0x08 returned by ST7580_DlData function. This code is not listed in Table 14 of the user manual. What causes this error?

This topic has been closed for replies.
Best answer by Didier HERROUIN

Code 0x08 is an ERR_TIMEOUT : the Sub-System aborts operation due to internal timeout

1 reply

Didier HERROUIN
Didier HERROUINBest answer
Technical Moderator
January 17, 2024

Code 0x08 is an ERR_TIMEOUT : the Sub-System aborts operation due to internal timeout