As shematic below the pin7 is connected to GND so there will be a 60uA leakage .so how to disable the internal pull up by config the register.

 

EthanYao_0-1705304200906.png

 

 

 

This topic has been closed for replies.
Best answer by Federica Bossi

Hi @EthanYao ,

Unfortunately is not possible to disable the internal pull up on the pin 7.

1 reply

Federica Bossi
Federica BossiBest answer
Technical Moderator
January 18, 2024

Hi @EthanYao ,

Unfortunately is not possible to disable the internal pull up on the pin 7.