Skip to main content
Associate III
November 29, 2023
Solved

MEMS IMP23ABSU microphone

  • November 29, 2023
  • 1 reply
  • 1163 views

Hi, is the sensitivity in the datasheet (-38 dBV +-1) normalized to 1 Pa (e.g. -38 dB re 1V/Pa)?

This topic has been closed for replies.
Best answer by Federica Bossi

Hi @TomRett ,

IMP23ABSU has a sensitivity of -38dBV with an input of a 1kHz sound wave of amplitude 1 Pascal rms (=94dBSPL)

1 reply

Federica Bossi
Federica BossiBest answer
Technical Moderator
November 29, 2023

Hi @TomRett ,

IMP23ABSU has a sensitivity of -38dBV with an input of a 1kHz sound wave of amplitude 1 Pascal rms (=94dBSPL)

In order to give better visibility on the answered topics, please click on 'Accept as Solution' on the reply which solved your issue or answered your question.