Skip to main content
Associate
January 6, 2026
Solved

The power consumption of LIS2MDL in power-down mode

  • January 6, 2026
  • 2 replies
  • 340 views

Hi,everyone.

I measured the power consumption of LIS2MDLTR on the same board in power-down mode.

and found that the LIS2MDL chip on STEVAL-MKI217V1(from mouser) consumes less power than the LIS2MDL purchased separately from mouser.

We have some question and need your help.

  1.  What is the power consumption LIS2MDL in power-down mode ? 
  2.  Why do the parameter differ between LIS2MDL chip on STEVAL-MKI217V1 and LIS2MDL purchased separately?
Best answer by Federica Bossi

Hi @young ,

The typical current consumption in PD mode is 1.5uA, as written in the datasheet.

How much difference did you measure between the two parts? It could be part-part variability.

2 replies

Federica Bossi
Federica BossiBest answer
Technical Moderator
January 8, 2026

Hi @young ,

The typical current consumption in PD mode is 1.5uA, as written in the datasheet.

How much difference did you measure between the two parts? It could be part-part variability.

In order to give better visibility on the answered topics, please click on 'Accept as Solution' on the reply which solved your issue or answered your question.
youngAuthor
Associate
January 14, 2026

Hi,@Federica Bossi,

The consumption in PD mode that I measured is 70 ~ 80uA.

The power consumption of the component deviates significantly from the typical consumption.

 

Federica Bossi
Technical Moderator
January 16, 2026

Hi @young ,

How are you testing the LIS2MDL? There may be an error in your board design that is causing extra power consumption.

In order to give better visibility on the answered topics, please click on 'Accept as Solution' on the reply which solved your issue or answered your question.