Skip to main content
Evelina CAMILLERI
ST Employee
November 11, 2022
Solved

What is the peak power consumption of ISPU core under "full load"?

  • November 11, 2022
  • 1 reply
  • 665 views

..

    This topic has been closed for replies.
    Best answer by Luca SEGHIZZI

    The peak power consumption depends on the different use cases, for instance we did some benchmarking on the different ISPU examples and some consumptions are the following: AXL calibration 11uA, gyro calibration 26uA, magnetometer calibration 21uA, wrist tilt 4uA, human activity recognition 27uA, man down 14uA

    1 reply

    Luca SEGHIZZI
    Luca SEGHIZZIBest answer
    Senior
    November 11, 2022

    The peak power consumption depends on the different use cases, for instance we did some benchmarking on the different ISPU examples and some consumptions are the following: AXL calibration 11uA, gyro calibration 26uA, magnetometer calibration 21uA, wrist tilt 4uA, human activity recognition 27uA, man down 14uA