Best answer by Peter BENSCH

Even if the thread is older, here is a short answer that may help others.

Yes, this should be possible, if the user program does not rely on the product id and/or rev level, because the replacement just provides more memory.

Regards

/Peter

1 reply

Peter BENSCH
Peter BENSCHBest answer
Technical Moderator
July 27, 2021

Even if the thread is older, here is a short answer that may help others.

Yes, this should be possible, if the user program does not rely on the product id and/or rev level, because the replacement just provides more memory.

Regards