VIPER011XS BUCK topology

  • April 12, 2022
  • 4 replies
  • 1497 views

0693W00000LxkCPQAZ.pngCould someone explain why POWER EARTH and GND (PIN 1) are tied togheter?

This not make sense for me.

This topic has been closed for replies.
Best answer by Peter BENSCH

The best way to show this is with a drawing:

0693W00000LxkpgQAB.pngRegards

/Peter

4 replies

Peter BENSCH
Technical Moderator
April 12, 2022

Welcome, @APC.1​, to the community!

You got confused by the symbols:

  • the three dashes of different lengths indicate power earth
  • the small white triangle is an internal connection of the schematic that must not be connected to ground

This representation was chosen because the VIPer011 is actually a flyback converter whose GND pin is not connected to GND in this buck converter, but realizes the output.

Does it answer your question?

Regards

/Peter

APC.1
APC.1Author
Associate
April 12, 2022

We need to conect +VOUT 25.8VCC and power earth instead GND?

Peter BENSCH
Peter BENSCHBest answer
Technical Moderator
April 12, 2022

The best way to show this is with a drawing:

0693W00000LxkpgQAB.pngRegards

/Peter

APC.1
APC.1Author
Associate
April 12, 2022

Great!! exactily what I did.

Peter BENSCH
Technical Moderator
April 13, 2022

Excellent!

If the problem is resolved, please mark this topic as answered by selecting Select as best under your preferred answer. This will help other users find that answer faster.