Hello,

I got a error message during control project genaration

"

It is not possible to create a motor control project with the FOC algorithm using the selected hardware

. No proper path for motor control signals was found for the following mandatory features:
- Phase Voltage Generation

- Current Sensing

For more details, please, look at the following log file in your home directory: .st_workbench/connectAlgo.log

"

, but it was unable to find connectAlgo.log in the folder \AppData\Local\STMicroelectronics\MC_SDK_6.3.2\Utilities\PC_Software\STMCWB\.

Best answer by GMA

Hello @Creative_Stone,

File is located in home directory: ~/.st_workbench

1 reply

GMA
GMABest answer
Technical Moderator
April 18, 2025

Hello @Creative_Stone,

File is located in home directory: ~/.st_workbench