June 11, 2020
Question

Rest RDP Read Protection

  • June 11, 2020
  • 3 replies
  • 1187 views

Hi, I have the STM32F427VI, I don't know how this happend but now is read/write protected Level1. How can I reset this, I want to disable read protection at all to burn my application.

Now I can't read the memory 0693W000001qVU5QAM.pngwith STM Utility with J-TAG and coudn't erase memory with Demonstrator GUI via RS232. Please see the attached image.

This topic has been closed for replies.

3 replies

TDK
Super User
June 11, 2020

Uncheck all sectors on the bottom and change Read Out Protection in the top-left to Level 0 and apply.

"If you feel a post has answered your question, please click ""Accept as Solution""."
As.51
As.51Author
Associate III
June 11, 2020

I tried this but I get the error: Could not set Option bytes!

Please see the attached picture. Thank you for your help:)0693W000001qWgbQAE.png

Piranha
Principal III
June 11, 2020

Set "Connect Under Reset" and do full chip erase.

As.51
As.51Author
Associate III
June 15, 2020

This is not working. Please see the images attached

0693W000001qjM5QAI.png

0693W000001qjLvQAI.png

As.51
As.51Author
Associate III
June 15, 2020

I managed with the option bytes to remove the read only but when I conenct with JTAG I still get the message that the MCU is ready only0693W000001qjSwQAI.png

As.51
As.51Author
Associate III
June 15, 2020

I managed to do it by removing all jumpers in the board.Thanks!