Skip to main content
_0x4d
Visitor II
February 8, 2023
Question

CubeMX Initializes wrong default USART peripheral on NUCLEO-C031C6

  • February 8, 2023
  • 1 reply
  • 747 views

STM32CubeMX version 6.7.0

CubeMX initializes USART1 peripheral on NUCLEO-C031C6 by default.

But USART2 is actually connected to ST-LINK VCP wire.

0693W00000YAIu8QAH.png0693W00000YAIuIQAX.png

This topic has been closed for replies.

1 reply

Simon.T
ST Employee
February 9, 2023

Hello @_0x4d​ ,

I confirmed the issue and I reported it internally in order to fix it.

Internal ticket number: 145172 (This is an internal tracking number and is not accessible or usable by customers).

Thanks for your feedbacks,

Best regards,

Simon