Question

ASM330LHB performance data

  • October 7, 2024
  • 1 reply
  • 746 views

My team is looking at what performance data ST has on file for the ASM330LHB. Specifically ​random walk and bias stability performance of accelerometers and gyros over the entire operating temperature range (-40C to 105C).

    This topic has been closed for replies.

    1 reply

    Technical Moderator
    October 8, 2024

    Hi @hmiller ,

    You find this information on DS13773. You can look at Section 4 "Module specifications ".

    hmillerAuthor
    Visitor II
    October 8, 2024

    Hi @Federica Bossi, page 10 of the datasheet lists these figures under a test condition of 25 degC. Is there any data for these figures (symbols VRW, XL_BI, ARW, G_BI) over the full range of operating temperatures?

    Technical Moderator
    October 8, 2024

    Hi @hmiller ,

    No, unfortunately we can't provide this information.