Skip to main content
Visitor II
May 11, 2021
Solved

How to choose the right total acquisition time?

  • May 11, 2021
  • 1 reply
  • 854 views

I use IIS3DWB vibration sensor. I set maximum bandwidth 6.3 kHz and FFT size 2048. What acquisition time should I use when using MotionSP library?

    This topic has been closed for replies.
    Best answer by niccolò

    Hi @JTam.1​ ,

    I would say that you need at least 2x6.3 ksamples to respect Nyquist, , so with an ODR of 26.667 kHz you would need half a second per acquisition.

    Niccolò

    1 reply

    ST Employee
    May 11, 2021

    Hi @JTam.1​ ,

    what ODR are you working with?

    Niccolò

    JTam.1Author
    Visitor II
    May 11, 2021

    The ODR of IIS3DWB vibration sensor is 26667 Hz with bandwidth 6.3 kHz.

    niccolòAnswer
    ST Employee
    May 11, 2021

    Hi @JTam.1​ ,

    I would say that you need at least 2x6.3 ksamples to respect Nyquist, , so with an ODR of 26.667 kHz you would need half a second per acquisition.

    Niccolò