Skip to main content
Visitor II
May 20, 2025
Question

Iis3dwb temperature leads to sampling rate deviation and inaccurate FFT

  • May 20, 2025
  • 1 reply
  • 348 views

Hello ST engineer, our company is currently using your iis3dwb MEMS sensor. We have encountered an issue where we have found that its sampling rate is not the standard 26667 in different environments and varies depending on temperature. Additionally, during frequency domain conversion, the frequency spectrum waveform is shifted due to inaccurate sampling rate input. Do you have a solution to this problem? We have tried linear interpolation, but the effect has been poor.

SsfChen_0-1747722173822.png

 

    This topic has been closed for replies.

    1 reply

    SsfChenAuthor
    Visitor II
    May 20, 2025

    SsfChen_0-1747730694238.pngSsfChen_1-1747730706630.png

    The error is still high even after using this register for calculation。

    Technical Moderator
    June 26, 2025

    Hi @SsfChen ,

    Is the variation you observed aligned to the value reported on the datasheet?

    FedericaBossi_0-1750945929627.png