[iis3dwb] What are the units of the BDR_XL registor?

  • March 12, 2024
  • 2 replies
  • 1111 views

Adjusting the register values below seems to adjust the time at which data is written to the buffer.

HKim23_0-1710207022327.png

 

I understood that the value is similar to Data Sampling frequency.

If i set the value to 6, about 1900 data per second will be written to the buffer.
I would like to know the exact units of that value.

    This topic has been closed for replies.

    2 replies

    Technical Moderator
    March 12, 2024

    Hi @HKim.23 ,

    It is the batching data rate and the unit is Hz.

    HKim.23Author
    Explorer
    March 12, 2024

    if BDR_XL is 0b1010, Batching Data Rate is 26667Hz.

    Then, if BDR_XL is 0b0110, what is the Batching Data Rate?

     

    Technical Moderator
    March 26, 2024

    Hi @HKim.23 ,

    As written in the application note, the only two possible configurations are 0000 (default) or 1010 (26667Hz):

     