Hi, do you have data and information about infrasound characteristics of MP34DT06J

I looked at its frequency response in the data sheet, but information is being plotted starting from 100 Hz only. 

I'm using the CCA02M2 board.

Many thanks!

    This topic has been closed for replies.

    2 replies

    ST Employee
    February 25, 2020

    Hi @MSant.1​ , what do you mean with "infrasound" characteristics? The usual characterizations is performed in the [20Hz, 20kHz] band, so I can share you a typical frequency response in this range from characterization lab. The FR is almost +-2dB flat down to 30Hz.

    0690X00000DXFjYQAX.png

    Btw which is your target application?

    Regards

    MSant.11Author
    Visitor II
    February 25, 2020

    Hi, sound from combustion processes may be in infrasound range, i. e. below 20 Hz. This is my target application.

    ST Employee
    February 25, 2020

    Hi @MSant.1​ , ok, I can share you the average behavior down to 10Hz, because the standard detailed characterization is limited to 20Hz.

    0690X00000DXH8tQAH.png

    Regards