Skip to main content
Visitor II
November 12, 2013
Question

Is there a specification for change in zero rate level vs time?

  • November 12, 2013
  • 1 reply
  • 604 views
Posted on November 13, 2013 at 00:38

If I measure the zero rate level for a few seconds, I can get an average measurement and use it to cancel out drift. However, the zero rate level changes over time. I want to choose a gyro with the smallest drift. How is change in zero rate level specified in the data sheet? I can't find it.

Thanks,

Osman
    This topic has been closed for replies.

    1 reply

    Visitor II
    November 18, 2013
    Posted on November 18, 2013 at 15:34

    Hello Osman,

    What is the gyroscope that you are referencing?

    For L3GD20, the attached datasheet contains on page 9, table 3 a section showing the zero-rate behavior depending on the FS.

    Please let me know if this was the information that you were looking for.

    Thank you,

    Thiago Reis

    ________________

    Attachments :

    L3GD20.pdf : https://st--c.eu10.content.force.com/sfc/dist/version/download/?oid=00Db0000000YtG6&ids=0680X000006HzJ0&d=%2Fa%2F0X0000000bJk%2FfWdyM6cBTKVQIGMdWGWpsNRgS6SekzNB_Y.KsNAyK_s&asPdf=false