Skip to main content
Visitor II
October 17, 2017
Question

LIS3DSH past pocessing temperature issues

  • October 17, 2017
  • 2 replies
  • 1157 views
Posted on October 17, 2017 at 15:56

Dear all,

We use LIS3DSH and we have issues after reflowing process.

In fact values are not compensate correctly between -30�C to + 65�C; we have hysteresis and breaking.

Measurements are out of specifications .

See attached good and bad component.

Only reflow process seems to affect correct measurement of the component 

Thanks for help

#hysteresis #lis3dsh-temperature-issues #reflow-process
    This topic has been closed for replies.

    2 replies

    ST Employee
    October 18, 2017
    Visitor II
    October 18, 2017
    Posted on October 18, 2017 at 10:30

    Hi,

    Yep regarding guideline.

    Additionaly we have same bad results with ST evaluation board after reflowing new component on it.

    Reflow profils are corrects also !!

    We have 2%  good result in production.

    Thanks for help.

    ST Employee
    October 23, 2017
    Posted on October 23, 2017 at 16:32

    Can you please provide us your reflow profile?