LSM6DSLTR high current consumption
Hi,
We found a problem with high current by using LSM6DSLTR.
LSM6DSLTR is used to trigger system from sleep mode.
The normal system sleep current is 0.5~0.9mA.
The abnormal one becomes 3.25mA.
This issue is related with this LSM6DSLTR IC.
When we replaced this new IC, this current will fall into normal range.
When we swapped this IC from normal and abnormal units, this high current occurs in suspected defect IC.
IC Data code is 221.
LSM6DSLTR supports for 3D accelerometer and 3D gyroscope, but gyroscope is disenable in this moment.
May you give advice if there is any potential problem for hardware circuit or firmware setting? The schematic related LSM6DSLTR is updated for your reference.
Best regards,
Lawrence Fu