Dear Sir,

Our project using LSM6DSO IMU to detect the position, the sensor temperature is very high after power on and Initialization, it's over 80 degree, I think it's abnormal, I attach the sch, can you give some suggestions, thanks a lot.

    This topic has been closed for replies.
    Best answer by Federica Bossi

    Hi @Jali ,

    No, if INT2 is not used, leave it floating or connect it to ground through a resistor as per datasheet recommendations.

    1 reply

    Technical Moderator
    October 23, 2025

    Hi @Jali ,

    I confirm you that such a temperature value is abnormal. Here are some suggestions:

    • Ensure the sensor is powered at the correct voltage (typically 1.8 V for LSM6DSO). Overvoltage can cause excessive power dissipation and heating.
    • Ensure no shorts or wiring mistakes on the I2C lines or chip pins that could cause excessive current draw.
    • Start with the sensor in low-power or power-down mode and verify temperature behavior before enabling full operation.
    • Use an IR thermometer or thermal camera to confirm the actual sensor temperature.
    JaliAuthor
    Visitor II
    October 24, 2025

    Hi  Federica,

    we connect the INT2 pin to vcc directly, is it right?

     

    Technical Moderator
    October 28, 2025

    Hi @Jali ,