Hi.i am using LMS6DSR ,and use ODR is 208Hz,but,i found that i can't get 208 samples at 1 secend.and,i had confirmed that it only about 203 Hz from Interrupt signal.so,i want to know is that normal? i can't find information about error of ODR in datasheet.

    This topic has been closed for replies.
    Best answer by Eleon BORLINI

    Hi @Pqing.1​ ,

    please note that usually, on the datasheets, the ODR is defined only at its typical value, in this case 208Hz.

    I can share with you a distribution of the ODR 208Hz on a representative validation sample: if you need a precise characterization of the ODR, you should measure it sample by sample (e.g. counting the DRDY signal). I can tell you that the jitter (i.e. the repeatability of the ODR for each single device) is much less than the spread among ODR actual values.

    0693W00000BbHRRQA3.png 

    If my reply answered your question, please click on Select as Best at the bottom of this post. This will help other users with the same issue to find the answer faster. 

    -Eleon

    2 replies

    ST Employee
    June 17, 2021

    Hi @Pqing.1​ ,

    please note that usually, on the datasheets, the ODR is defined only at its typical value, in this case 208Hz.

    I can share with you a distribution of the ODR 208Hz on a representative validation sample: if you need a precise characterization of the ODR, you should measure it sample by sample (e.g. counting the DRDY signal). I can tell you that the jitter (i.e. the repeatability of the ODR for each single device) is much less than the spread among ODR actual values.

    0693W00000BbHRRQA3.png 

    If my reply answered your question, please click on Select as Best at the bottom of this post. This will help other users with the same issue to find the answer faster. 

    -Eleon

    Pqing.1Author
    Visitor II
    June 18, 2021

    Ok,thanks for your answer, i have a question about typical value is that why select 208Hz why not mean or 3 sigma?

    ST Employee
    June 18, 2021

    well, it's a typical value coming from the internal clock tree downsampling, and it could vary among samples and lots (but constant on same sample).

    -Eleon