Question

Thermal response

  • February 4, 2023
  • 2 replies
  • 1051 views

One of the critical measurements for the analysis of bridges is the thermal response. The 201/109 combination has an average thermal response in the FFT of 1.5 milli-g - it is slightly frequency dependent, but ignoring that the standard deviation means that below 3.5 milli-g is just Gaussian data. Anything over 3.5 is structural response, statistically speaking. The 3.5 milli-g is higher than other accelerometers we use, do you have some device with a tighter response to thermal?

    This topic has been closed for replies.

    2 replies

    Technical Moderator
    April 6, 2023

    Ciao @Macneacail​,

    For your application, I suggest you to look at IIS2ICLX and let me know if you need more information.

    Visitor II
    April 6, 2023

    It is 2 axis only, of no use in bridges, but we are testing the 201/109 in 12 locations, so we will know a lot more in 12 months.