Question

What is MP23ABS1TR start up time?

  • April 1, 2020
  • 1 reply
  • 690 views

What time is needed for MP23ABS1TR is ready after power On?

(The idea is to decrease MP23ABS1TR current consuption by power strobing)

BR, Oleg

    This topic has been closed for replies.

    1 reply

    ST Employee
    April 1, 2020

    Hi @OPush​ , the MP23ABS1TR dataout is ready (i.e. the sensitivity falls inside +-1dB guardband with respect to the long-term settled value) after less then 10ms from the power up event. You can decrease the current consumption lowering the Vdd value, but i suggest you to stay above 2V in order not to decrease the overall THD performances. Regards