Question

ADC always busy

  • December 13, 2006
  • 1 reply
  • 639 views
Posted on December 13, 2006 at 05:26

ADC always busy

    This topic has been closed for replies.

    1 reply

    Visitor II
    December 12, 2006
    Posted on December 12, 2006 at 15:49

    I am using an ST10F276 and I find that the ADBSY bit is always set after startup, long after the 40.629 clock pulses have passed for ADC initialisation. I do not configure the ADC so all registers contain their reset values. I have a 2.5V reference connected to the VAREF pin and a 22uF capacitor between VAREF and VAGND.

    Can anyone help?