Hello,

 

My system is required to operate at -40C.

The datasheet states that low range ambient temperature is -30C, while the junction temperature is -40C.

Alex_Kucherov_0-1749408500626.png

Can you please explain the discrepancy between the two? Under what conditions can the junction temperature be lower than the ambient temperature?

Can I use the ECMF02-4CMX8 in my case?

 

Thank you in advance.

    This topic has been closed for replies.
    Best answer by FGUIT

    Hello,

    The ECMF02-4CMX8 can be used at -40°C.

    Datasheet will be modified with Top between -40°C and +85°C.

    Best regards.

    Fabrice.

    3 replies

    Super User
    June 9, 2025

    > Can I use the ECMF02-4CMX8 in my case?

    > My system is required to operate at -40C.

    > The datasheet states that low range ambient temperature is -30C

    If you want to remain within the allowable limits of the datasheet, no this doesn't work. It's a bit odd, but that's what the DS says and we have no reason to distrust it. It's also on rev 4.

    Visitor II
    June 10, 2025

    Hi TDK, 

    It would still be helpful to understand the reason for the -30C limit, since as you mentioned, it is a bit odd. 

    Does the -40C junction temperature refer to the TVS diodes while the -30C is limited by the common mode filter?  

     

    FGUITAnswer
    ST Employee
    June 11, 2025

    Hello,

    The ECMF02-4CMX8 can be used at -40°C.

    Datasheet will be modified with Top between -40°C and +85°C.

    Best regards.

    Fabrice.

    ST Employee
    June 23, 2025

    Good morning, my name is Arnaud Fardoit, I'm product marketing engineer in charge of filtering/protectino products for US region. We have been informed that our ECMF02-4CMX8 is going to be phase out very soon and not recommended for new design anymore. We recommend our ECMF2-40A100N6 for datalines, our ESDA17P20-1F2 for VBUS line and ESDZV5H-1BU2 for ID line. My colleague Fabrice has been informed about the change, sorry for the inconvenienced caused. Best Regards, Arnaud