Hi.I use stpm32 as metering chip.The protocol what I use is SPI.why the sign of reactive energy is wrong but the sign of active energy is correct?

  • July 3, 2021
  • 5 replies
  • 2376 views

The amount of reactive energy register is decreased while I expect it to be increased.I use a reference meter" to ensure the sign of reactive energy.what should I do?

Could my stpm32 chip be fake?

    This topic has been closed for replies.
    Best answer by Mpanj.1

    Hello @SBEN .2​ 

    I changed the chip with a new one that I bought from another online shop.

    All problems asked, were resolved.

    The old chip was fake.

    Best regards.

    5 replies

    Visitor II
    July 4, 2021

    Hello @Mpanj.1​ ,

    If you suspect that the chip is fake, please provide a high resolution photo of the said chip.

    Otherwise, check the value of OFRx[8:0], it might be causing the issue.

    0693W00000BclwbQAB.png 

    Best regards,

    @SBEN .2​ 

    Mpanj.1Author
    Visitor II
    July 5, 2021

    Hello @SBEN .2 ,

    Thank you for your answer.

    The value of the active and reactive energy is correct but the sign of reactive energy is wrong.

    I tested the chip in 230V and 10A and +45 degrees phase difference with a reference meter.But the problem still remains.

    I send a photo of my chip.

    Thanks.

    Visitor II
    July 5, 2021

    Hello @Murtaza Panju​ ,

    Are you sure that Phase and Neutral aren't switched up?

    Best regards,

    @SBEN .2​ 

    Mpanj.1Author
    Visitor II
    July 5, 2021

    Hello @SBEN .2​ 

    I am sure because the sign of active power is correct and the value of active energy register is increased as i expect.But the value of reactive energy register is decreased and the sign of reactive power is negative.

    The load i was applied is inductive.

    The error measurment is less than 0.2%.

    Thanks.

    Mpanj.1AuthorAnswer
    Visitor II
    October 31, 2021

    Hello @SBEN .2​ 

    I changed the chip with a new one that I bought from another online shop.

    All problems asked, were resolved.

    The old chip was fake.

    Best regards.