Skip to main content
Visitor II
March 18, 2005
Question

ICP programming differnece between ST7 DVP and Softec tool?

  • March 18, 2005
  • 3 replies
  • 818 views
Posted on March 18, 2005 at 04:47

ICP programming differnece between ST7 DVP and Softec tool?

    This topic has been closed for replies.

    3 replies

    hg-chenAuthor
    Visitor II
    December 29, 2004
    Posted on December 30, 2004 at 00:16

    phenomenon:

    ST72F324K6TC used, programming via ICP with ST7MDT20-DVP3,

    after finish programming program memory, and before programming the option byte, there is a message

    ''Please set the Option Bytes as 'Read Protect Disable' '',

    but the option byte setting is E747H, which is read protect disable!

    after then it can not be read nor erase!

    but using Softec Indart tool, it is OK!

    any possible explanation for above condition?

    hg-chenAuthor
    Visitor II
    January 5, 2005
    Posted on January 05, 2005 at 05:57

    Thanks a lot for your comments!

    hg-chenAuthor
    Visitor II
    March 17, 2005
    Posted on March 17, 2005 at 23:14

    Sorry for late reply!

    the S/W version of STVP is around 1.6.x !

    can you help answer another question,

    why I read out a programmed ST72F324K6TC ,

    and the option byte is FF FF!!

    to my understanding , FF FF can not even be set via STVP!