Skip to main content
Visitor II
July 17, 2020
Question

M95M02 is no working?

  • July 17, 2020
  • 3 replies
  • 906 views

0693W000001t4sVQAQ.png0693W000001t4qPQAQ.png

Working way: W and Hold is high, Other SPI BUS.

First we send "RDSR" Command but MISO is low like no working, so I try send "WREN" and "WRSR"but is no working.

    This topic has been closed for replies.

    3 replies

    ST Employee
    July 17, 2020

    ​Hello,

    Even if MISO is low after RDSR doesn't mean it doesn't work. Status register content = 0x00 will give you MISO = low.

    Please try  WREN + RSDR. You should have WEL bit = 1

    (confirm your hexa command)

    BR

    Team EEPROM suPPort

    Ljie.1Author
    Visitor II
    July 18, 2020

    I find the answer.

    your datasheet :

    1.Before accepting the execution of the Write and Write Status register instructions, the

    device checks whether the number of clock pulses comprised in the instructions is a

    multiple of eight​.

    so: send“RSDR"+"0xff".

    Ljie.1Author
    Visitor II
    July 18, 2020

    Thanks Team EEPROM suPPort