Skip to main content
Visitor II
March 30, 2006
Question

not ISO 7816-3 compliant ?

  • March 30, 2006
  • 1 reply
  • 669 views
Posted on March 30, 2006 at 11:45

not ISO 7816-3 compliant ?

    This topic has been closed for replies.

    1 reply

    danteAuthor
    Visitor II
    March 30, 2006
    Posted on March 30, 2006 at 11:45

    Hi everybody,

    i am wondering about the data in the specification of the ''STR71x MICROCONTROLLER FAMILY'' there is ISO 7816-3 asynchronous protocol specification that does not match to the Data in this spec. ETU Data for parity error is specified to be 11 ETU. ISO 7816-3 specifies 10.5 +/- 0.2 so this means this interface is not compliant to specification......

    Is there a mistake?

    best regards and thanks in advance.

    dB