Skip to main content
Visitor II
April 16, 2003
Question

PROBLEM with ST72F324 LVD feature !!!

  • April 16, 2003
  • 2 replies
  • 936 views
Posted on April 16, 2003 at 06:27

PROBLEM with ST72F324 LVD feature !!!

    This topic has been closed for replies.

    2 replies

    Visitor II
    April 15, 2003
    Posted on April 15, 2003 at 12:07

    I use the 324µC since several months and I just discover in the last datasheet (march 2003 / page 160) that the LVD operation is not guarantee. What does it mean. Can you please tell me more details concerning this marginality and in which working area LVD works ??? thank you

    Visitor II
    April 16, 2003
    Posted on April 16, 2003 at 06:27

    It is expected to be fixed in next revision.

    For this cut, it means that LVD operation cannot be guaranteed in any conditions (particularly at operating conditions limits).