Question

Programming ST7FLITE29 whit ST7MDT10-EPB, programming mode: ICP OPT Enable

  • February 21, 2003
  • 3 replies
  • 870 views
Posted on February 21, 2003 at 12:18

Programming ST7FLITE29 whit ST7MDT10-EPB, programming mode: ICP OPT Enable

    This topic has been closed for replies.

    3 replies

    ulisesAuthor
    Visitor II
    February 18, 2003
    Posted on February 18, 2003 at 22:22

    Hi, I am new programming ST7 microcontrollers. I want to program the ST7FLITE29 whit the ST7MDT10-EPB programmer through ICC connector but I get the following message:

    Hardware configuration set to .

    Blank check before programming (when available) is OFF

    Verify after programming is ON.

    Clear memory before loading a file is ON.

    Erase device memory before programming (when available) is OFF

    Display a popup window when an error occurs is ON.

    Log activity is OFF

    > Reading PROGRAM MEMORY area... Error : Cannot communicate with the device ! Option Bytes are Enabled on the device Check the ICC cable connection and check all the needed pin connections on the ICP connector Try the other programming mode:'ICP OPT Disable' in order to check the Options Bytes on the device (Clock Source,PLL,LVD) compare to the application configuration

    I have the following connection: attachment

    Could you help me whit this little problem?

    ________________

    Attachments :

    connection.doc : https://st--c.eu10.content.force.com/sfc/dist/version/download/?oid=00Db0000000YtG6&ids=0680X000006I0BQ&d=%2Fa%2F0X0000000bUw%2F51msWQH.D8dilEnzWTeG5pBVWsPXfw0YwFmFsj3ca9Y&asPdf=false
    Visitor II
    February 19, 2003
    Posted on February 19, 2003 at 06:20

    Hi,

    If you are using the STVP7 programmer, do the following:

    go to configure -> configure ST visual programmer

    Ensure the ST7MDT10-EPB is selected

    Ensure the LPT port is correct

    select ICP OPT DISABLE for programming mode.

    This should work now.

    with the OPT enabled, the clock mode could be incorrect or the WDG may be operating.

    both of these may prevent programming.

    hope this helps

    Simon

    [ This message was edited by: sjh on 12-11-2003 16:20 ]
    Visitor II
    February 21, 2003
    Posted on February 21, 2003 at 12:18

    Hi

    You must connect VDD to ICC connector pin 7. ST7MDT10-EPB needs this VDD as voltage reference. Then, as you have not connected ICC connector clock (pin 9), you must use ICP OPT Enable. If you want to use ICP OPT Disable you must connect clock from ICC connector pin 9 to ST7-OSC1. But, for ST72FLITE29, it is better to do not connect this ICC-clock and to use ICP OPT enable.

    Pierre Tarayre