Skip to main content
Visitor II
July 30, 2013
Question

ST7FLITE29 Write Protect

  • July 30, 2013
  • 1 reply
  • 676 views
Posted on July 30, 2013 at 12:08

Hi

I have a new build PCB with a ST7Flite29 fitted, I cant program the device, I have had to run an external clock signal to Clk In (PB4), the programmer is now reporting ''Write Protected'', how do I get this back, the ERASE device is greyed out on the STVP programmer

Regards, Brian
    This topic has been closed for replies.

    1 reply

    ST Employee
    August 12, 2013
    Posted on August 12, 2013 at 14:39

    Hello,

    Normally, a brand new ST7 should not be write protected.

    Anyway, in STVP, read option bytes and then just change the option bit FMP_W ''WRITE protection'' to OFF and reprogram the options bytes.

    Then, you can reprogram the program memory.(If the FMP_R is OFF too).

    Rgds,

    Laurent