STGAP3Sxx datasheet error - DS14758 Rev 2

  • November 19, 2025
  • 0 replies
  • 73 views

I assume that in the truth table in page 14 of DS14758 Rev 2:

SteveC1_0-1763552814744.png

The low & high values in the final column should all be shifted down by one. i.e.

nRSTIN+IN-GOUT
LXXLOW
HLLLOW
HHLHIGH
HLHLOW
HHHLOW