Question

USB R12 & R42

  • August 29, 2003
  • 2 replies
  • 729 views
Posted on August 29, 2003 at 16:40

USB R12 & R42

    This topic has been closed for replies.

    2 replies

    Visitor II
    May 17, 2011
    Posted on May 17, 2011 at 11:55

    I read with my multimeter R12 = 7.58k & R42 = 13.95k. is that correct?

    Second, on the DK3200's schematic, R12 = 4.7K and R42 = N/S...

    Is there any problem or the multimeter reading is correct?

    Regards

    Visitor II
    May 17, 2011
    Posted on May 17, 2011 at 11:55

    There is nothing wrong with your multimeter, I got the same values with my multimeter too. I bet if you remove R12 from the circuit, it will measure 4.7K. R42 is not installed on the DK3200 eval board.