0693W00000LxkCPQAZ.pngCould someone explain why POWER EARTH and GND (PIN 1) are tied togheter?

This not make sense for me.

    This topic has been closed for replies.
    Best answer by Peter BENSCH

    The best way to show this is with a drawing:

    0693W00000LxkpgQAB.pngRegards

    /Peter

    4 replies

    Technical Moderator
    April 12, 2022

    Welcome, @APC.1​, to the community!

    You got confused by the symbols:

    • the three dashes of different lengths indicate power earth
    • the small white triangle is an internal connection of the schematic that must not be connected to ground

    This representation was chosen because the VIPer011 is actually a flyback converter whose GND pin is not connected to GND in this buck converter, but realizes the output.

    Does it answer your question?

    Regards

    /Peter

    APC.1Author
    Visitor II
    April 12, 2022

    We need to conect +VOUT 25.8VCC and power earth instead GND?

    Technical Moderator
    April 12, 2022

    The best way to show this is with a drawing:

    0693W00000LxkpgQAB.pngRegards

    /Peter

    APC.1Author
    Visitor II
    April 12, 2022

    Great!! exactily what I did.

    Technical Moderator
    April 13, 2022

    Excellent!

    If the problem is resolved, please mark this topic as answered by selecting Select as best under your preferred answer. This will help other users find that answer faster.