    Best answer by Travis Palmer

    Hi PDiet,

    for simply turning on the field it is sufficient to execute the startup procedure. (including Regulator adjustment and AAT)-

    Afterwards you can enable the carrier by turning on the "en" and "tx_en" bit.

    BR Travis

    1 reply

    ST Employee
    December 1, 2020

    Hi PDiet,

    for simply turning on the field it is sufficient to execute the startup procedure. (including Regulator adjustment and AAT)-

    Afterwards you can enable the carrier by turning on the "en" and "tx_en" bit.