Mifare Classic with CR95HF
I am trying to use the CR95HF to read mifare classic tags. I am trying to send the authentication with key a command. I have been monitoring the communications between the CR95HF and the card using a proxmark.
I am certain I am sending the authentication command correctly as I can see the response Token RB. However the CR95HF is returning a timeout (ie it seems as if there is a short time out running and it is timing out before the response is received).I notice on page 19 of the CR95HF datasheet it says ''Note that REQA, WUPA,Select20 and Select70commands use a fixed intervalof 86/90 μs between a requestand its reply. Other commandsuse a variable interval withfixed granularity.'' I'm wondering if I need to adjust the frame wait time? If so are there any recommendations for what I set the PP and MM bits to? Otherwise does anyone have any ideas as to what I might be doing wrong?