Skip to main content
Visitor II
May 11, 2021
Solved

ST25RU3993 : Is the power output is calibrated? What would be the tolerance.?

  • May 11, 2021
  • 1 reply
  • 571 views

When I set the tx power as 25 dBm in the application what would be output tolerance.

What would be the output power accuracy?

We understand that tolerance resolution would be the parameter to drive the step size.

Regards

Prabhu

    This topic has been closed for replies.
    Best answer by Bart Herse

    Dear Skann.1,

    For both readers ST25RU3993-EVAL and ST25RU3993-HPEV the output power level is not calibrated.

    A closed-loop output power control can be implemented using the power detector that is present on the boards.

    The output power level resulting to 25 dBm is for both readers at Ant1:

    • ETSI: -7
    • FCC: -6

    For the tolerances you can expect approx. +/- 1.2 dB

    I hope this information is helpful.

    Cheers,

    B

    1 reply

    Visitor II
    May 27, 2021

    Dear Skann.1,

    For both readers ST25RU3993-EVAL and ST25RU3993-HPEV the output power level is not calibrated.

    A closed-loop output power control can be implemented using the power detector that is present on the boards.

    The output power level resulting to 25 dBm is for both readers at Ant1:

    • ETSI: -7
    • FCC: -6

    For the tolerances you can expect approx. +/- 1.2 dB

    I hope this information is helpful.

    Cheers,

    B