write time ?

  • February 17, 2014
  • 3 replies
  • 1151 views
Posted on February 17, 2014 at 09:54

hi , 

1.what is the page size in M24SR-16  ?  in the datasheet its declared  that 

   write time for page in I2C = 5ms , write time for up to 264 bytes =150ms 

2.Is it normal after writing 5 bytes to the  M24SR , i am getting Frame extension of            

   2*9.6ms ?

3.when authenticating using password in order to gain Read / Write Access , does it much    time as writing 16 bytes ?

#fwi #m24sr #i2c #m24sr #ndef
    This topic has been closed for replies.
    Best answer by Anais GALLIGANI
    Posted on March 05, 2014 at 11:42

    Hello,

    Please find here below answer to each point

     

    1. In Scenario  1,3  the R-APDU  you got is 036A824F75     =>  SW1=6A  SW2=82   ,which means   ''File or Application Not Found''  (Table 24 Datasheet) , So the Write Process Didn't Start .
    • This mean the sequence applied was not correct .

    • Before to access or update a NDEF  it is need to

      • s

        elect correctly the application

      • Select correctly the file

    • Then you can access the file for reading or writing

    2.In Scenario 2,4 the S-Block  you got is F2020A72   , Which is Frame Extension request from the IC.

    • F2 service Instruction  (waiting time extension , no DID)

    • 02 WTX parameter

    • 0A72   CRC

    • The M24SR calculate by itself the requested time extension parameter WTX  in function of the Update request .

    • In your case WTX parameter is equal to “02â€�

    • The reader Must Acknowledge by sending the same service instruction thus in your case  F202  0A72

    • After what the update will start .

    Have a nice day,

    Best Regards,

    ST NFC/RFID Dynamic tag e2e support

    3 replies

    Visitor II
    February 19, 2014
    Posted on February 19, 2014 at 18:41

    Hello,

    °) 16 byte ,  but the M24SR is organized in file ,

    So the write time is function of several parameters :

    -

             

    If we change or not the message Length (offset 00 but physically outside the user area)  (1  programming time)

    -

             

    the number N of physical  page supporting the message  ( N * programming time)

    -

             

    and FWI = 9.6 ms authorizing only 1 Prog

    Thus

    1)

         

    Change P1P2 :  1 prog , No extension

    02-19-2014 16:33:16         NFC SEND I-Block

                                                    >>> CR95HFDLL_SENDRECV,

    0300D6000002000BB889

    08

                                                    <<< 8008 

    036A824F75

      080000

    2)

         

    Change P1P2 :  1 prog + 1 byte ,    2  Prog    ,  Extension request ->  Accept extension  , Pog OK

    02-19-2014 16:37:40         NFC SEND I-Block

                                                    >>> CR95HFDLL_SENDRECV,

    0300D6000003000BD1F5E2

    08

                                                    <<< 8007

    F2020A72

    080000

    02-19-2014 16:37:40         NFC SEND SWTX_Block

                                                    >>> CR95HFDLL_SENDRECV,

    F2020A72

    08

                                                    <<< 8008

    0390002D53

    080000

    3)

         

    Change  14 byte , first row (except P1P2)     1  Prog      , Pog OK

    02-19-2014 16:31:51         NFC SEND I-Block

                                                    >>> CR95HFDLL_SENDRECV,

    0200D600020ED1011F55017777772E73742E636FCE80

    08

                                                    <<< 8008

    026A82932F

      080000

    4)

         

    Change  2 byte , first & second row      2  Prog    ,  Extension request ->  Accept extension  , Pog OK

    02-19-2014 16:40:53         NFC SEND I-Block

                                                    >>> CR95HFDLL_SENDRECV,

    0200D6000F02636FE1D0

    08

                                                    <<< 8007

    F2020A72

      080000

    02-19-2014 16:40:53         NFC SEND SWTX_Block

                                                    >>> CR95HFDLL_SENDRECV,

    F2020A72

    08

                                                    <<< 8008

    029000F109

    080000

    2°)  For me the first extension occurs when programming on two page  ,

    Don’t forget to respond to a Service command  “Waiting time Extensionâ€� request ie:

    F2020A72

     by the same Service command ie:

    F2020A72

    3°) Yes this is normal , purpose to prevent from hacking by increasing the command  time ( there is none physical writing)

    I hope this is clear enough,

    Best regards,

    ST NFC/RFID Dynamic support

    eyals111Author
    Visitor II
    February 23, 2014
    Posted on February 23, 2014 at 11:55

    Thanks for the quick reply ,

    1. In Scenario  1,3  the R-APDU  you got is 

    036A824F75

         =>  SW1=6A  SW2=82   ,

    which means   ''File or Application Not Found''  (Table 24 Datasheet) , So the Write Process Didn't Start .

    2.

    In Scenario 2,4 

    the S-Block  you got is 

    F2020A72   ,

    Which is Frame Extension request from the IC.

    from what understand page size is 16 Bytes , but there are few exception :

    1.If i change the NDEF message length bytes , it will take 1 Prog time .

    2.The Number of Page I am crossing during Write , Number of Page * 

    Prog time

    If you can clarify your reply I really appreciate.

    Visitor II
    March 5, 2014
    Posted on March 05, 2014 at 11:42

    Hello,

    Please find here below answer to each point

     

    1. In Scenario  1,3  the R-APDU  you got is 036A824F75     =>  SW1=6A  SW2=82   ,which means   ''File or Application Not Found''  (Table 24 Datasheet) , So the Write Process Didn't Start .
    • This mean the sequence applied was not correct .

    • Before to access or update a NDEF  it is need to

      • s

        elect correctly the application

      • Select correctly the file

    • Then you can access the file for reading or writing

    2.In Scenario 2,4 the S-Block  you got is F2020A72   , Which is Frame Extension request from the IC.

    • F2 service Instruction  (waiting time extension , no DID)

    • 02 WTX parameter

    • 0A72   CRC

    • The M24SR calculate by itself the requested time extension parameter WTX  in function of the Update request .

    • In your case WTX parameter is equal to “02â€�

    • The reader Must Acknowledge by sending the same service instruction thus in your case  F202  0A72

    • After what the update will start .

    Have a nice day,

    Best Regards,

    ST NFC/RFID Dynamic tag e2e support