Question

Error in UM2408 on LD1 connection

  • October 29, 2019
  • 1 reply
  • 560 views

There is an error in UM2408 regarding the connections for LD1.

In section "6.6 LEDs", it currently reads:

User LD1: a green user LED is connected to the STM32H7 I/O PB0 (SB39 ON and SB47

OFF) or PA5 (SB65 ON and SB54 OFF) corresponding to the ST Zio D13.

It should read:

User LD1: a green user LED is connected to the STM32H7 I/O PB0 (SB54 ON and SB65

OFF) or PA5 (SB65 ON and SB54 OFF) corresponding to the ST Zio D13.

https://www.st.com/resource/en/user_manual/dm00499171.pdf

    This topic has been closed for replies.

    1 reply

    Technical Moderator
    October 30, 2019

    Hello @TDK​ ,

    Thank you for reporting this error. We will correct this in the next release of UM2408.

    Best Regards,