The Automatic mode in the ST-LINK Utility hangs whenever I press the START button.

I've seen on the forum similar problems with version J28. The solution was to downgrade the ST-LINK debugger to J27. Does the J29 version have the same bug?

Is there any planned release for addressing this bug?

    This topic has been closed for replies.
    Best answer by Tesla DeLorean

    >>Is there any planned release for addressing this bug?

    Isn't J32 current? Does the issue still exist there?

    https://www.st.com/en/development-tools/stsw-link007.html

    3 replies

    Technical Moderator
    October 18, 2018

    Hello @jean-philippe Rey​ ,

    Which version of ST-Link Utility and STLinkUSBDriver.dll are you using ?

    Please try to use the latest ST-Link Utility version 4.2.0.

    Kind Regards,

    Imen

    Graduate II
    October 18, 2018

    >>Is there any planned release for addressing this bug?

    Isn't J32 current? Does the issue still exist there?

    https://www.st.com/en/development-tools/stsw-link007.html

    Visitor II
    October 22, 2018

    Thanks @Community member​ for pointing me to this version. It works fine with the Automatic mode! (and with St-Link Utility 4.2.0.0).

    Best regards,