['F446 documentation] SPDIF-Rx - sync_done

  • January 16, 2018
  • 1 reply
  • 801 views
Posted on January 16, 2018 at 15:48

In RM0390 rev.3, in Figure 347. SPDIFRX States, sync_done internal signal is mentioned (and nowhere else). Isn't it the same as SPDIFRX_SR.SYNCD, at least from the programmer's point of view? If so, please replace sync_done by SPDIFRX_SR.SYNCD in that figure, which removes unnecessary confusion (and also allows to remove the note in that figure).

JW

    This topic has been closed for replies.
    Best answer by Imen.D

    Hi @waclawek.jan ,

    The figure is already updated in the RM0390 version available on ST web page.

    Thank you again for your valuable feedback; it is much appreciated!

    I closed this post.