How to calibrate the MSIS hardware autocalibration of the stm32u5

  • May 23, 2025
  • 1 reply
  • 604 views

 

 

Hi. I am currently using the stm32u545ret6q mcu.

 

Looking at the RCC of reference documentation(RM0456) it says that it has MSIS hardware autocalibration, but the example code(AN5676) only shows how to adjust the trimming value.

 

Do you have any example code that shows how to do hardware auto-calibration?

 
 
    This topic has been closed for replies.
    Best answer by mƎALLEm

    Hello,

    To my knowledge there is no example for MSIS hardware autocalibration. But from reference manual states the following:

    mALLEm_0-1749480986847.png

    So you need to use the PLL-mode hardware auto-calibration feature, ensure the LSE oscillator is connected and operational and configure the RCC_CR register to enable PLL-mode (MSIPLLEN and MSIPLLSEL bits).