We are integrating the STL library in the context of a project requiring IEC 61508 safety integrity level 2 (SIL2). How can we programmatically pull the version info out of the STL library? The API doesn't show anything to that effect. Also, what's the latest version we shall use?

    This topic has been closed for replies.
    Best answer by Amel NASRI

    Hi @DamienF​ ,

    In the STL package you received, you should have all required details regarding how to achieve a defined SIL level. Then, you need to operate with FMEA/FMEDA results to prove the required level is covered.

    Regarding the STL library version, it is provided in the ReleaseNote file within the package.

    As this package is provided under NDA, it is recommended to be in touch with your FAE for farther deep answers to your questions.

    -Amel

    2 replies

    Technical Moderator
    July 2, 2021

    Hi @DamienF​ ,

    In the STL package you received, you should have all required details regarding how to achieve a defined SIL level. Then, you need to operate with FMEA/FMEDA results to prove the required level is covered.

    Regarding the STL library version, it is provided in the ReleaseNote file within the package.

    As this package is provided under NDA, it is recommended to be in touch with your FAE for farther deep answers to your questions.

    -Amel

    DamienFAuthor
    Visitor II
    July 8, 2021

    Yes I have follow up questions/suggestions and have contacted my local FAE. Thanks!