Skip to main content
Graduate II
January 2, 2023
Solved

The OPAMP_CSR_OPARANGE bit in NUCLEO-U575ZI-Q is not shown during debug mode

  • January 2, 2023
  • 2 replies
  • 996 views

Hello everyone!

I have just noticed that The OPAMP_CSR_OPARANGE bit in NUCLEO-U575ZI-Q is not shown during debug mode. Some bug perhaps?..

0693W00000Y7EHuQAN.jpg

    This topic has been closed for replies.
    Best answer by KDJEM.1

    Hello @Skfir​,

    Thank you for bringing this issue our attention.

    I confirm the issue: The 31 bit filed "OPA_RANGE" for the OPAMP1_CSR register is missing in the STM32U5.svd file.

    I reported internally.

    Internal ticket number: 142108 (This is an internal tracking number and is not accessible or usable by customers).

    Kaouthar

    2 replies

    KDJEM.1Answer
    Technical Moderator
    January 3, 2023

    Hello @Skfir​,

    Thank you for bringing this issue our attention.

    I confirm the issue: The 31 bit filed "OPA_RANGE" for the OPAMP1_CSR register is missing in the STM32U5.svd file.

    I reported internally.

    Internal ticket number: 142108 (This is an internal tracking number and is not accessible or usable by customers).

    Kaouthar

    Technical Moderator
    August 25, 2025

    Hello @Skfir ;

     

    The issue is fixed in https://www.st.com/resource/en/svd/stm32u5_svd.zip version 1.3.

    Thank you for your contribution in STCommunity.

     

    Kaouthar