Skip to main content
Visitor II
September 2, 2020
Question

wrong IS_RCC_PLLN_VALUE macro

  • September 2, 2020
  • 2 replies
  • 774 views

Hi !

This issue is still not fixed in the current F4 firmware V1.25.

If USE_FULL_ASSERT is used the parameter check for a valid calculated value of PLLN=96 by STM32CubeMx fails.

The old issue was closed therefore please raise a ticket (again) - thanks !

Best regards,

Michael.

    This topic has been closed for replies.

    2 replies

    Technical Moderator
    September 8, 2020

    Good catch @Katzenberger.Michael​ ! Thanks for bringing again this limitation to our attention.

    It is requested again to make the required update after reporting it to our development team.

    -Amel

    Visitor II
    October 8, 2020

    Please fix it.