Can i connect J-Link to test points TP2,TP3,TP4,TP5,TP8,TP9 and not use the embedded ST-Link/V2 ?

  • May 1, 2020
  • 1 reply
  • 1065 views

Can i connect J-Link to test points TP2,TP3,TP4,TP5,TP8,TP9 and not use the embedded ST-Link/V2 ? If yes do it needs special treatment like disabling embedded ST-Link/V2 ?

    This topic has been closed for replies.

    1 reply

    Technical Moderator
    May 4, 2020

    Hello,

    Yes, you could use these points for an external probe.

    Should work without specific embedded ST-Link disable (obviously, to avoid conflicts, you must not start any debugging session on ST-Link), and you could still use UART4 VCP thru ST-Link USB.

    Please ensure you have the latest ST-Link FW.