Question

Can all selected channel's sampling in each SAR ADC(0-2) be trigged by the same timer so that their samples can be synchronized ?

  • November 23, 2024
  • 1 reply
  • 417 views

Hi,

Can all selected channel's sampling in each SAR ADC(0, 1, 2) be trigged by the same timer with the same settings so that their sample can be synchronized ?

Thanks

    This topic has been closed for replies.

    1 reply

    Technical Moderator
    December 26, 2024

    Hi @RongShengWang 

    Yes, it's possible to synchronize all three ADCs to acquire three different channels at the same time by using a same external trigger.

    Thanks,

    ELABI.1